HIOKI 4371

HIOKI 4371

Home / HIOKI 4371

HIOKI 4371

Hioki clamp meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. Model CM4371 is a 600A True RMS clamp meter that features stronger jaws, broader -25°C to 65°C operating temperature range and IP54 dustproof and waterproof enclosure to enable professionals to work quickly in tough situations including the development, repair, and maintenance of equipment and devices such as electric vehicles. Additionally, the high-voltage DC measurement capability of up to 1700 V (*1) is ideal for the clamp maintenance inspections of electrical and solar power equipment.  

Specifications

 
DC Current range 20.00 A/600.0 A, Basic accuracy: ±1.3% rdg. ±0.08 A (20 A range)
AC Current range 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy: ±1.3% rdg. ±0.08 A (at 20 A)
Crest factor 20.00 A range: 7.5 600.0 A range: 3 or less
DC+AC Current range 20.00 A/600.0 A (10 Hz to 1 kHz, True RMS), Basic accuracy DC, 45-66 Hz: ±1.3% rdg. ±0.13 A (at 20 A)
DC Voltage range 600.0 mV to 1700 V (*1), 5 ranges, Basic accuracy: ±0.5% rdg. ±0.5 mV (at 600 mV)
AC Voltage range 6.000 V to 1000 V, 4 ranges (15 Hz to 1 kHz, True RMS), Basic accuracy 45 – 66 Hz: ±0.9% rdg. ±0.013 V (at 6 V)
DC+AC Voltage range 6.000 V to 1000 V, 4 ranges, Basic accuracy DC, 45 – 66 Hz: ±1.0% rdg. ±0.023 V (at 6 V)
Resistance range 600.0 Ω to 600.0 kΩ, 4 ranges, Basic accuracy: ±0.7% rdg. ±0.5 Ω (at 600 Ω)
Capacitance range 1.000 μF to 1000 μF, 4 ranges, Basic accuracy: ±1.9% rdg. ±0.005 μF (at 1 μF)
Frequency range 9.999 Hz to 999.9 Hz, 3 ranges, Basic accuracy: ±0.1% rdg. ±0.003 Hz (at 9.999 Hz)
Temperature (K) -40.0 to 400.0 ˚C, add temperature probe accuracy to basic accuracy of ±0.5% rdg. ±3.0 ˚C
Voltage detection Hi: 40 V to 600 V AC, Lo: 80 V to 600 V AC, 50/60 Hz
Other functions Automatic AC/DC detection, Plus/Minus judgement function of DC A, DC V, Max/Min/Average/PEAK MAX/ PEAK MIN value display, Filter function, Display value hold, Auto hold, Back light, Auto-power save, Buzzer sounds, Zero-adjustment
Dustproof, waterproof Grip: IP54 (when measuring an insulated conductor only), Jaw (the current sensor portion of the instrument)/ barrier: IP50 *Risk of electric shock from the conductor being measured increases when wet.
Power supply LR03 Alkaline battery ×2, Continuous use 45 hr (Backlight OFF)
Core jaw diameter φ33 mm (1.30 in), Jaw dimension: 69 mm (2.72 in) W× 14 mm (0.55 in) D
Dimensions and mass 65 mm (2.56 in) W × 215 mm (8.46 in) H × 35 mm (1.38 in) D mm, 340 g (12.0 oz)
Accessories TEST LEAD L9207-10, CARRYING CASE C0203, LR03 Alkaline battery ×2, Instruction Manual×1