Fluke 8846A
Home / Fluke 8846A
Fluke 8846A
Product overview Product overview: Fluke 8845A 6.5 Digit Precision Multimeter
The Fluke 8845A 6.5 digit precision multimeter handles your most demanding measurements on the bench or in a system. It measures volts, ohms, and amps, with basic V dc accuracy of up to 0.0024%, 10 A current range, and a wide ohms range. The 8845A also measures frequency and period. The functions of a counter, capacitance meter, and thermometer are built in. Graphical display modes include Trendplot™ paperless recorder mode, statistics and hist histograms.Dual display and graphical capabilities
A dual display lets you measure two parameters of the same signal from one test connection. Use the unique analyze mode to view data as a real time trend plot or histogram.Perform 4-wire measurement with only two leads
Patented split terminal jacks for the 2 x 4 ohms function let you perform 4-wire measurements using only two leads instead of four.Multiple connectors give you maximum flexibility
Serial, IEEE-488, and Ethernet interfaces come standard.FlukeView® Software and drivers add PC power and application compatibility
FlukeView Forms lets you document, store and analyze individual readings or series of measurements, then convert them into professional-looking documents. Instrument programming drivers, DLL files and support information are included to get your test system up and running as quickly as possibleFlukeView® Forms Basic
The Fluke 8845A ships with a free copy of FlukeView Basic. For a larger array of forms or to use FlukeView Forms Designer to customize your forms, upgrade to FlukeView Forms with FVF-UGg>Fluke 45 and Agilent 34401A emulation
The 8845A emulates operation and programming commands of the Fluke 45 and Agilent 34401.Specifications Specifications: Fluke 8845A 6.5 Digit Precision Multimeter
Technical Specifications | ||
Display | VFD dot matrix | |
Resolution | 6.5 Digits | |
V DC | Range | 100 mV to 1000 V |
Max. resolution | 100 nV | |
Accuracy | 8845A: 0.0035 + 0.0005 (% measurement + % of range) | |
V AC | Range | 8845A: 100 mV to 750 V |
Max. resolution | 100 nV | |
Accuracy | 8845A: 0.06 + 0.03 (% measurement + % of range) | |
Frequency | 3 Hz to 300 KHz | |
Resistance | 2 x 4 Wire | Yes |
Range | 8845A: 100 Ω to 100 MΩ | |
Max. resolution | 8845A: 100 μΩ | |
Accuracy | 8845A: 0.010 + 0.001 (% measurement + % of range) | |
A DC | Range | 100 μA to 10 A |
Max. resolution | 100 pA | |
Accuracy | 0.050 + 0.005 (% measurement + % of range) | |
A AC | Range | 8845A: 10 mA to 10 A |
Max. resolution | 8845A: 10 nA | |
Accuracy | 0.10 + 0.04 (% measurement + % of range) | |
Frequency | 3 Hz to 10 kHz | |
Freq/period | Range | 8845A: 3 Hz to 300 kHz |
Max. resolution | 1 μHz | |
Accuracy | 0.01% | |
Continuity / diode test | Yes | |
Math functions | NULL, Min/Max/Average, Std Dev | |
dB/dBm | Yes | |
Advanced functions | Statistics/histogram | Yes |
Trendplot | Yes | |
Limit test | Yes | |
Input output | ||
Interfaces | RS 232, IEE-488.2, Ethernet, USB (with optional adaptor) | |
General Specifications | ||
Weight | 3.6 kg (8.0 lbs) | |
Dimensions | 88 x 217 x 297 mm (3.46 x 8.56 x 11.7 in) | |
Calibration documentation | 17025 accredited report of calibration included | |
Safety | Designed to comply with IEC 61010-1:2000-1, UL 61010-1A1, CAN/CSA-C22.2 No. 61010.1, CAT I 1000V/CAT II 600V |