Advanced diagnostic and logging functionality for maximizing productivity

The DT-9989 represents the next generation of high performance industrial logging millimeters, including higher accuracies and greater troubleshooting convenience than ever before. With the ability to log data and review it graphically on large colored display, you can solve problems faster and help minimize downtime, while working at several locations. The DT-9989 incorporates a built in 10MHz DSO that is the rugged solution for industrial troubleshooting and installation applications. It’s a truly integrated test tool, with oscilloscope, multimeter and “paperless” recorder in one affordable, easy-to-use instrument. Find answers to problems in machinery, instrumentation, control and power systems quickly and easily.

FEATURES

Enclosure Double molded, waterproof
Shock (Drop Test) 6.5 feet (2 meters)
Diode Test Test current of 0.9mA maximum, open circuit voltage 3.2V DC typical
Continuity Check Audible signal will sound if the resistance is less than 25Ω (approx.), test current <0.35mA
PEAK Captures peaks >1ms
Temperature Sensor Requires type K thermocouple
Input Impedance >10MΩ VDC & >9MΩ VAC
AC Response True RMS
AC True RMS The term stands for “Root-Mean-Square” which represents the method of calculation of the voltage or current value. Average responding multimeters are calibrated to read correctly only on sine waves and they will read inaccurately on non-sine wave or distorted signals. True rms meters read accurately on either type of signal.
ACV Bandwidth 50Hz to 100000Hz
Crest Factor
Display 50,000 count backlit liquid crystal with bargraph
Overrange indication “OL” is displayed
Auto Power Off 5-30minutes (approximately) with disable feature
Polarity Automatic (no indication for positive); Minus (-) sign for negative
Measurement Rate 20 times per second
Battery One7.4V
Fuses mA, μA ranges; 0.5A/1000V ceramic fast blow A range; 10A/1000V ceramic fast blow
Operating Temperatur 5°C to 40°C (41°F to 104°F)
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Operating Humidity Max 80% up to 31°C (87°F) decreasing linearly to 50% at 40°C (104°F)
Storage Humidity <80%
Operating Altitude 7000ft. (2000meters) maximum
Safety This meter is intended for origin of installation use and protected, against the users, by double insulation per EN61010-1 and IEC61010-1 2nd Edition (2001)to Category IV 600V and Category III 1000V; Pollution Degree 2. The meter also meets UL 61010-1, 2nd Edition (2004), CAN/CSA C22.2 No. 61010-1 2nd Edition (2004),and UL 61010B -2-031, 1st Edition (2003)